Safe use

What our parts are for, and what they're not

Tydro parts are installation aids, site consumables, markers and non-critical replacement parts. Read the limits before you use one. If you're not sure, ask us on WhatsApp first.

Material guide

MaterialUse it forLimits
PETGIndoor tools, jigs, gauges and temporary site parts.Softens at about 75 °C. Indoor use, out of direct sun. Not for flues, geyser outlets or parts that stay in a live wireway.
ASAAnything outdoors, in the sun, on a roof or on a solar installation, and parts that stay on a wireway long term.UV-stable and handles heat up to about 95 °C. Still a plastic: not a structural or load-rated part.
TPUFlexible push-in plugs and seals for site protection.Flexible and tough, but not heat-resistant. Temporary use only.
PLANothing we sell.We don't use PLA for anything near cables, outdoors or near hot water. It softens at about 55–60 °C.

Heat figures are typical for the material, not a rating for a finished part.

Limits that apply to everything

  • Not for drinking water or the pressure path. Nothing Tydro sells goes in a potable water system or anywhere under mains pressure. No flush valves, float valves, tap internals or pressure-test plugs. Flush buttons and tap handles or caps are non-wetted parts only.
  • Not electrical enclosures or accessories. We don't make junction boxes, DB blanking plates, or socket and switch parts.
  • Cable items are dressing and organisation only, never the sole means of support. Never use them in escape routes.
  • No sleeves through walls, floors or fire breaks. Printed plastic is not a fire stop.
  • Conduit tools stay out of the fixed installation. They protect, check, mark and cut. Slab plugs come out before cables go in.
  • Drain grates fit over compliant (SABS-marked) drains. The grate is a cover, not part of the drain.
  • Downpipe and gutter adaptors are for rainwater only.
  • Debris caps are temporary site protection, not a permanent stop end.
  • Not structural. Don't use any Tydro part to carry a load it wasn't made for.
  • Tydro parts carry no third-party approval. The installer remains responsible for the installation meeting the rules that apply to it.

Use limits by product

Conduit slab and brickwork plugs

TPU · 20 mm / 25 mm / 32 mm

  • Temporary site protection, not a permanent stop end.
  • Pull the plug before drawing in cables.
  • Not a sleeve or a fire stop.

Hinge jig, shelf-pin jig and depth stops

PETG · 35 mm hinge / 5 mm shelf pin

  • Drilling guides only. Clamp the work before drilling.

Pipe debris caps

PETG · 40 mm / 50 mm / 110 mm

  • Temporary site protection, not a permanent stop end.
  • Never use as a test plug or anywhere in the pressure path.
  • Not for potable water pipes.
  • Take the cap off before you connect the pipe.

Tile pipe-hole centre-finder and drill guide

PETG · 15/22 mm / 40/50 mm

  • Drilling guide only.
  • Use a bit made for the tile, at the speed the bit maker gives.
  • Don't let a hot bit rest against the guide.

Conduit bend-radius gauge

PETG · 20 mm / 25 mm / 32 mm

  • Checking tool only.
  • It checks the radius, not the bore. Look for kinks or flattening too.

Snap-on pipe ID markers

PETG · 15–22 mm / 28–40 mm / 50 mm / 110 mm

  • Identification only. Not a pipe clip, clamp or support.
  • Fits over the outside of the pipe. Nothing touches the water.
  • Indoor use, on pipes no hotter than 60 °C.

Solar and inverter accessories

ASA · Per installation

  • Dressing and organisation only — never the sole means of support.
  • Never in escape routes.
  • Not an enclosure, and not part of the inverter, battery or distribution board.

Cable combs

ASA · Per cable size

  • Dressing and organisation only — never the sole means of support.
  • Never in escape routes.

Conduit circuit-ID clips

ASA · 20 mm / 25 mm / 32 mm

  • Identification only. Not a cable support or a conduit fixing.
  • Doesn't replace the labelling the installation needs.

Rough-in depth bracket

PETG · 15 mm / 22 mm

  • Positioning aid only, not a permanent pipe support.
  • Sits on the outside of the fitting. Never in contact with the water.
  • Check the depth against the mixer maker's installation sheet.

Flush box setting jig

PETG · 20 mm entry / 25 mm entry

  • Setting tool only. It comes off once the box is fixed.
  • Works with standard wall boxes. Tydro doesn't make boxes.

Sanitaryware set-out template kit

PETG · Basin / WC / Geyser

  • Marking and set-out only.
  • Always check centres against the fitting maker's installation sheet.

Chase depth and width gauge

PETG · 20 mm / 25 mm

  • Measuring tool only.

Odd-size shower and floor-drain grates

ASA · Made to measure

  • Fits over compliant (SABS-marked) drains. The grate is a cover, not part of the drain.
  • Foot traffic only. Not for vehicle loads.
  • Not for potable water.

Downpipe and gutter adaptors

ASA · Made to measure

  • Rainwater only.
  • Not for sewer, waste or potable water.

Square-cut saw guide and deburr cone

PETG · 20 mm / 25 mm / 32 mm

  • Hand tool for PVC conduit only.

Draw-wire leader and pulling head

PETG · 20 mm / 25 mm

  • For drawing cables into empty conduit that is not live.
  • Pull by hand.

Conduit fill reference tag

PETG · Pocket size

  • Quick reference only. The person signing off the installation checks the fill.