Safe use
What our parts are for, and what they're not
Tydro parts are installation aids, site consumables, markers and non-critical replacement parts. Read the limits before you use one. If you're not sure, ask us on WhatsApp first.
Material guide
| Material | Use it for | Limits |
|---|---|---|
| PETG | Indoor tools, jigs, gauges and temporary site parts. | Softens at about 75 °C. Indoor use, out of direct sun. Not for flues, geyser outlets or parts that stay in a live wireway. |
| ASA | Anything outdoors, in the sun, on a roof or on a solar installation, and parts that stay on a wireway long term. | UV-stable and handles heat up to about 95 °C. Still a plastic: not a structural or load-rated part. |
| TPU | Flexible push-in plugs and seals for site protection. | Flexible and tough, but not heat-resistant. Temporary use only. |
| PLA | Nothing we sell. | We don't use PLA for anything near cables, outdoors or near hot water. It softens at about 55–60 °C. |
Heat figures are typical for the material, not a rating for a finished part.
Limits that apply to everything
- Not for drinking water or the pressure path. Nothing Tydro sells goes in a potable water system or anywhere under mains pressure. No flush valves, float valves, tap internals or pressure-test plugs. Flush buttons and tap handles or caps are non-wetted parts only.
- Not electrical enclosures or accessories. We don't make junction boxes, DB blanking plates, or socket and switch parts.
- Cable items are dressing and organisation only, never the sole means of support. Never use them in escape routes.
- No sleeves through walls, floors or fire breaks. Printed plastic is not a fire stop.
- Conduit tools stay out of the fixed installation. They protect, check, mark and cut. Slab plugs come out before cables go in.
- Drain grates fit over compliant (SABS-marked) drains. The grate is a cover, not part of the drain.
- Downpipe and gutter adaptors are for rainwater only.
- Debris caps are temporary site protection, not a permanent stop end.
- Not structural. Don't use any Tydro part to carry a load it wasn't made for.
- Tydro parts carry no third-party approval. The installer remains responsible for the installation meeting the rules that apply to it.
Use limits by product
Conduit slab and brickwork plugs
TPU · 20 mm / 25 mm / 32 mm
- Temporary site protection, not a permanent stop end.
- Pull the plug before drawing in cables.
- Not a sleeve or a fire stop.
FTTH, Starlink, CCTV and router mounts
ASA · Per device
- Holds the device it was made for. Don't hang anything else from it.
- Fix with screws and plugs that suit the wall.
- Not a cable support.
Hinge jig, shelf-pin jig and depth stops
PETG · 35 mm hinge / 5 mm shelf pin
- Drilling guides only. Clamp the work before drilling.
Pipe debris caps
PETG · 40 mm / 50 mm / 110 mm
- Temporary site protection, not a permanent stop end.
- Never use as a test plug or anywhere in the pressure path.
- Not for potable water pipes.
- Take the cap off before you connect the pipe.
Tile pipe-hole centre-finder and drill guide
PETG · 15/22 mm / 40/50 mm
- Drilling guide only.
- Use a bit made for the tile, at the speed the bit maker gives.
- Don't let a hot bit rest against the guide.
Conduit bend-radius gauge
PETG · 20 mm / 25 mm / 32 mm
- Checking tool only.
- It checks the radius, not the bore. Look for kinks or flattening too.
Snap-on pipe ID markers
PETG · 15–22 mm / 28–40 mm / 50 mm / 110 mm
- Identification only. Not a pipe clip, clamp or support.
- Fits over the outside of the pipe. Nothing touches the water.
- Indoor use, on pipes no hotter than 60 °C.
Solar and inverter accessories
ASA · Per installation
- Dressing and organisation only — never the sole means of support.
- Never in escape routes.
- Not an enclosure, and not part of the inverter, battery or distribution board.
Cable combs
ASA · Per cable size
- Dressing and organisation only — never the sole means of support.
- Never in escape routes.
Conduit circuit-ID clips
ASA · 20 mm / 25 mm / 32 mm
- Identification only. Not a cable support or a conduit fixing.
- Doesn't replace the labelling the installation needs.
Rough-in depth bracket
PETG · 15 mm / 22 mm
- Positioning aid only, not a permanent pipe support.
- Sits on the outside of the fitting. Never in contact with the water.
- Check the depth against the mixer maker's installation sheet.
Flush box setting jig
PETG · 20 mm entry / 25 mm entry
- Setting tool only. It comes off once the box is fixed.
- Works with standard wall boxes. Tydro doesn't make boxes.
Sanitaryware set-out template kit
PETG · Basin / WC / Geyser
- Marking and set-out only.
- Always check centres against the fitting maker's installation sheet.
Odd-size shower and floor-drain grates
ASA · Made to measure
- Fits over compliant (SABS-marked) drains. The grate is a cover, not part of the drain.
- Foot traffic only. Not for vehicle loads.
- Not for potable water.
Downpipe and gutter adaptors
ASA · Made to measure
- Rainwater only.
- Not for sewer, waste or potable water.
Draw-wire leader and pulling head
PETG · 20 mm / 25 mm
- For drawing cables into empty conduit that is not live.
- Pull by hand.
Conduit fill reference tag
PETG · Pocket size
- Quick reference only. The person signing off the installation checks the fill.